"The accuracy of a laboratory in an industrial environment"

The characteristics of this automatic filling machine include: Dosing accuracy + / - 5 mg, automatic removal of doses that are not in the range of tolerance (for total compliance of the filling), automatic positioning of the tubes and check to prevent two feedings into the same tube.
Operation range:

Description / pictures:
Results : Set point: 130 mg, standard deviation: 1.12 mg

|
 |
Despite an environment that can be unfavorable for highly precise measurements (scales resolution: 0.1 mg), the results are remarkably accurate and stable (less than 2% of doses are out of tolerance). All out of tolerance doses, are automatically rejected and placed in a container for recycling. Traceability of the results on Excel sheets, provides a quick analysis of performance. |